EN

Earth's magnetic field in Santo Antônio da Patrulha

In Santo Antônio da Patrulha (Rio Grande do Sul, Brazil) the Earth's magnetic field has a strength of 22.4 µT (22,369 nanotesla). A compass needle points 18.3° west of true north. The field lines emerge from the ground at 43.0° to the horizontal.

29.82° S, 50.52° W · 118 m · Population: 42,947 · IGRF-14, November 2026

Magnetic field values for Santo Antônio da Patrulha

Total field strength
22.37 µT22,369 nT
Declination
18.26° W−5.9′ per year
Inclination
−43.04°field points out of the ground
Horizontal intensity
16.35 µT16,349 nT
Vertical intensity
−15.27 µTnegative = upward
North component
15.53 µT15,525 nT
East component
−5.12 µT−5,123 nT
Annual change of field
−24 nTper year
Geomagnetic latitude
−21.3°distance from the magnetic equator
N

True north Magnetic north

Compass declination in Santo Antônio da Patrulha

In Santo Antônio da Patrulha, magnetic north lies 18.3° west of true north. To turn a compass bearing into a map bearing, subtract 18.3° (true = magnetic − 18.3°); for the reverse, add it. The declination changes by −5.9′ per year, so older maps show an outdated value.

Southern lights in Santo Antônio da Patrulha

Santo Antônio da Patrulha lies at a geomagnetic latitude of −21.3°. Aurora is practically never visible here; only historic superstorms such as the Carrington Event of 1859 reached this far toward the equator.

Live aurora forecast and Kp index →

How the magnetic field in Santo Antônio da Patrulha has changed since 1900

Since 1900 the declination in Santo Antônio da Patrulha has shifted from 0.3° W to 18.3° W, and the field strength has changed by −15.7 % (from 26.5 to 22.4 µT).

−20.4−14.9−9.4−4.01.5190019251950197520002025
Declination in degrees (negative = west), 1900–2030
21.923.124.425.727.0190019251950197520002025
Total field strength in µT, 1900–2030
YearDeclinationInclinationTotal field strength (µT)
19000.3° W−22.1°26.53
19102.0° W−22.3°26.27
19203.9° W−22.9°25.93
19305.4° W−24.0°25.57
19406.6° W−25.2°25.26
19507.7° W−26.7°24.74
19609.1° W−27.9°24.28
197010.8° W−29.7°23.91
198012.4° W−31.7°23.60
199013.7° W−34.0°23.28
200014.9° W−36.2°23.02
201016.2° W−38.4°22.77
202017.6° W−41.2°22.52
202518.1° W−42.6°22.41
2030*18.6° W−43.9°22.30

* 2030: forecast based on the IGRF-14 secular variation.

Santo Antônio da Patrulha compared

Across the 2,278 cities in Brazil with more than 15,000 inhabitants, the average field strength is 24.1 µT and the average declination 20.9° W. Santo Antônio da Patrulha ranks 2,076 of 2,278 by field strength (1 = strongest).

Nearby cities

CityDistanceDeclinationµT
Rolante19 km18.3° W22.4
Osório25 km18.4° W22.4
Taquara31 km18.2° W22.4
Parobé37 km18.2° W22.3
Igrejinha38 km18.2° W22.4
São Francisco de Paula42 km18.4° W22.4

All cities in Rio Grande do Sul →

Frequently asked questions

How strong is the Earth's magnetic field in Santo Antônio da Patrulha?

About 22.4 µT (22,369 nanotesla) at ground level (IGRF-14, November 2026). Of this, 16.3 µT act horizontally and 15.3 µT vertically.

What is the magnetic declination in Santo Antônio da Patrulha?

The declination is 18.3° W: a compass points 18.3° west of true north. It currently changes by about −5.9′ (arc minutes) per year.

Can you see the southern lights in Santo Antônio da Patrulha?

Santo Antônio da Patrulha lies at a geomagnetic latitude of −21.3°. Aurora is practically never visible here; only historic superstorms such as the Carrington Event of 1859 reached this far toward the equator.

What is the magnetic inclination in Santo Antônio da Patrulha?

The field lines are inclined 43.0° to the horizontal and point out of the ground. A freely suspended magnetic needle tilts by this angle.

Is the magnetic field in Santo Antônio da Patrulha harmful?

No. At about 22 µT the Earth's field is roughly 224 times weaker than a fridge magnet and 134,111 times weaker than a 3-tesla MRI scanner. Life on Earth evolved in it.

Calculated with the International Geomagnetic Reference Field (IGRF-14) for November 2026 at 118 m above sea level. Local anomalies (ore deposits, steel structures, power lines) can cause deviations of several degrees. Method & sources