EN

Earth's magnetic field in Villa del Rosario

In Villa del Rosario (Norte de Santander Department, Colombia) the Earth's magnetic field has a strength of 31.3 µT (31,298 nanotesla). A compass needle points 10.1° west of true north. The field lines dip into the ground at 30.4° to the horizontal.

7.83° N, 72.47° W · 436 m · Population: 64,951 · IGRF-14, November 2026

Magnetic field values for Villa del Rosario

Total field strength
31.30 µT31,298 nT
Declination
10.12° W−9.8′ per year
Inclination
30.44°field points into the ground
Horizontal intensity
26.98 µT26,982 nT
Vertical intensity
15.86 µTpositive = downward
North component
26.56 µT26,562 nT
East component
−4.74 µT−4,743 nT
Annual change of field
−87 nTper year
Geomagnetic latitude
17.0°distance from the magnetic equator
N

True north Magnetic north

Compass declination in Villa del Rosario

In Villa del Rosario, magnetic north lies 10.1° west of true north. To turn a compass bearing into a map bearing, subtract 10.1° (true = magnetic − 10.1°); for the reverse, add it. The declination changes by −9.8′ per year, so older maps show an outdated value.

Northern lights in Villa del Rosario

Villa del Rosario lies at a geomagnetic latitude of 17.0°. Aurora is practically never visible here; only historic superstorms such as the Carrington Event of 1859 reached this far toward the equator.

Live aurora forecast and Kp index →

How the magnetic field in Villa del Rosario has changed since 1900

Since 1900 the declination in Villa del Rosario has shifted from 4.0° E to 10.1° W, and the field strength has changed by −18.7 % (from 38.5 to 31.3 µT). Around 1956 the agonic line (zero declination) passed over Villa del Rosario – since then the compass has pointed west of true north.

−12.1−7.7−3.31.15.5190019251950197520002025
Declination in degrees (negative = west), 1900–2030
30.332.634.837.139.4190019251950197520002025
Total field strength in µT, 1900–2030
YearDeclinationInclinationTotal field strength (µT)
19004.0° E33.2°38.48
19103.4° E34.7°38.59
19202.7° E36.5°38.65
19302.0° E37.7°38.62
19401.3° E38.3°38.66
19500.6° E38.0°38.37
19600.4° W37.5°37.68
19701.7° W36.8°36.73
19803.3° W36.4°35.74
19905.0° W35.8°34.88
20006.6° W34.8°33.93
20107.8° W33.6°32.90
20209.1° W31.7°31.91
20259.8° W30.8°31.46
2030*10.6° W29.9°31.02

* 2030: forecast based on the IGRF-14 secular variation.

Villa del Rosario compared

Across the 317 cities in Colombia with more than 15,000 inhabitants, the average field strength is 30.9 µT and the average declination 8.4° W. Villa del Rosario ranks 115 of 317 by field strength (1 = strongest).

Nearby cities

CityDistanceDeclinationµT
Los Patios3 km10.1° W31.3
San Antonio del Táchira4 km10.1° W31.3
Cúcuta9 km10.1° W31.3
Ureña10 km10.2° W31.3
El Zulia18 km10.1° W31.4
Capacho Nuevo18 km10.2° W31.3

All cities in Norte de Santander Department →

Frequently asked questions

How strong is the Earth's magnetic field in Villa del Rosario?

About 31.3 µT (31,298 nanotesla) at ground level (IGRF-14, November 2026). Of this, 27.0 µT act horizontally and 15.9 µT vertically.

What is the magnetic declination in Villa del Rosario?

The declination is 10.1° W: a compass points 10.1° west of true north. It currently changes by about −9.8′ (arc minutes) per year.

Can you see the northern lights in Villa del Rosario?

Villa del Rosario lies at a geomagnetic latitude of 17.0°. Aurora is practically never visible here; only historic superstorms such as the Carrington Event of 1859 reached this far toward the equator.

What is the magnetic inclination in Villa del Rosario?

The field lines are inclined 30.4° to the horizontal and point into the ground. A freely suspended magnetic needle tilts by this angle.

Is the magnetic field in Villa del Rosario harmful?

No. At about 31 µT the Earth's field is roughly 160 times weaker than a fridge magnet and 95,854 times weaker than a 3-tesla MRI scanner. Life on Earth evolved in it.

Calculated with the International Geomagnetic Reference Field (IGRF-14) for November 2026 at 436 m above sea level. Local anomalies (ore deposits, steel structures, power lines) can cause deviations of several degrees. Method & sources