EN

Earth's magnetic field in Pardés H̱anna Karkur

In Pardés H̱anna Karkur (Haifa District, Israel) the Earth's magnetic field has a strength of 45.5 µT (45,515 nanotesla). A compass needle points 5.0° east of true north. The field lines dip into the ground at 49.2° to the horizontal.

32.47° N, 34.98° E · 63 m · Population: 46,601 · IGRF-14, November 2026

Magnetic field values for Pardés H̱anna Karkur

Total field strength
45.51 µT45,515 nT
Declination
5.04° E+1.0′ per year
Inclination
49.18°field points into the ground
Horizontal intensity
29.75 µT29,752 nT
Vertical intensity
34.44 µTpositive = downward
North component
29.64 µT29,637 nT
East component
2.62 µT2,616 nT
Annual change of field
+39 nTper year
Geomagnetic latitude
29.3°distance from the magnetic equator
N

True north Magnetic north

Compass declination in Pardés H̱anna Karkur

In Pardés H̱anna Karkur, magnetic north lies 5.0° east of true north. To turn a compass bearing into a map bearing, add 5.0° (true = magnetic + 5.0°); for the reverse, subtract it. The declination changes by +1.0′ per year, so older maps show an outdated value.

Northern lights in Pardés H̱anna Karkur

Pardés H̱anna Karkur lies at a geomagnetic latitude of 29.3°. Aurora is practically never visible here; only historic superstorms such as the Carrington Event of 1859 reached this far toward the equator.

Live aurora forecast and Kp index →

How the magnetic field in Pardés H̱anna Karkur has changed since 1900

Since 1900 the declination in Pardés H̱anna Karkur has shifted from 2.3° W to 5.0° E, and the field strength has changed by +11.1 % (from 41.0 to 45.5 µT). Around 1920 the agonic line (zero declination) passed over Pardés H̱anna Karkur – since then the compass has pointed east of true north.

−3.1−0.91.43.65.8190019251950197520002025
Declination in degrees (negative = west), 1900–2030
40.541.943.344.746.1190019251950197520002025
Total field strength in µT, 1900–2030
YearDeclinationInclinationTotal field strength (µT)
19002.3° W44.3°40.98
19101.3° W44.4°41.00
19200.1° E45.1°41.28
19301.0° E45.8°41.83
19401.6° E46.4°42.60
19501.8° E46.8°43.32
19602.2° E47.2°43.79
19702.3° E47.3°43.98
19802.6° E47.4°44.14
19902.9° E47.7°44.23
20003.4° E48.1°44.39
20104.1° E48.5°44.70
20204.9° E48.9°45.19
20255.0° E49.1°45.44
2030*5.1° E49.3°45.64

* 2030: forecast based on the IGRF-14 secular variation.

Pardés H̱anna Karkur compared

Across the 110 cities in Israel with more than 15,000 inhabitants, the average field strength is 45.4 µT and the average declination 5.0° E. Pardés H̱anna Karkur ranks 44 of 110 by field strength (1 = strongest).

Nearby cities

CityDistanceDeclinationµT
Binyamina-Giv'at Ada5 km5.1° E45.5
Binyamina6 km5.1° E45.5
Or Akiva6 km5.0° E45.5
Kafr Qara8 km5.0° E45.5
Hadera8 km5.0° E45.5
Baqa al-Gharbiyye9 km5.0° E45.5

All cities in Haifa District →

Frequently asked questions

How strong is the Earth's magnetic field in Pardés H̱anna Karkur?

About 45.5 µT (45,515 nanotesla) at ground level (IGRF-14, November 2026). Of this, 29.8 µT act horizontally and 34.4 µT vertically.

What is the magnetic declination in Pardés H̱anna Karkur?

The declination is 5.0° E: a compass points 5.0° east of true north. It currently changes by about +1.0′ (arc minutes) per year.

Can you see the northern lights in Pardés H̱anna Karkur?

Pardés H̱anna Karkur lies at a geomagnetic latitude of 29.3°. Aurora is practically never visible here; only historic superstorms such as the Carrington Event of 1859 reached this far toward the equator.

What is the magnetic inclination in Pardés H̱anna Karkur?

The field lines are inclined 49.2° to the horizontal and point into the ground. A freely suspended magnetic needle tilts by this angle.

Is the magnetic field in Pardés H̱anna Karkur harmful?

No. At about 46 µT the Earth's field is roughly 110 times weaker than a fridge magnet and 65,913 times weaker than a 3-tesla MRI scanner. Life on Earth evolved in it.

Calculated with the International Geomagnetic Reference Field (IGRF-14) for November 2026 at 63 m above sea level. Local anomalies (ore deposits, steel structures, power lines) can cause deviations of several degrees. Method & sources